Expand your system with up to six keypads!
The wireless touch keypad will arm and disarm the Gen 2 security system with one passcode or RFID tag(s). It is connected to you alarm panel via the eV1527 433Mhz protocol. It's effective communication range can be up to 80 metres without obstacles. The internal lithium-ion rechargeable battery provides power operation for up to 6 months.
Note: The keypad will disarm the Gen 2 alarm panel with the keypad user passcode, one admin code and three user codes, or the RFID tags (max of 10 RFID tags). The keypad will not disarm the Gen 2 alarm system using the passcodes that you have programmed into the Gen 2 alarm panel itself. However you can program the keypad with the same passcodes that you programmed into the Gen 2 alarm panel.
Main Features
- Works with the OSI Alarm System Gen 2
- Convenient for Multiple Entry Points: Ideal for use at another door entry of the home, providing quick and easy access.
- Multi-User Codes: 1 Admin Code and 3 User Codes
- Proximity Sensor: Automatically lights up when you are near the keypad
- Includes 2 RFID Tags: Up to 10 RFID Tags can be used (RFID Protocol: 125Khz, 4100/4200
- Multiple Modes: Use to Away Arm, Disarm, and Stay Arm your alarm system.
- Easy Installation: Simple to install no wires (screws onto wall surface)
- 433MHZ Wireless, EV1527 RF encoding: Reliable wireless connectivity for seamless operation.
- Long-lasting Battery: Uses a 3.7V 1500mAH lithium battery, lasting up to 180 days on a single charge. Fully charges in just 2-3 hours.
- USB Charging Cable Included: Comes with a USB charging cable that plugs into a DC5V 1.0A power supply (any smartphone charger will work!).
- ADD Multiple Keypads: Up to 6 keypads can be paired with the Gen 2 alarm panel
What's Included?
- 1x Keypad
- 2 x RFID Tags
- 1 User Guide
- 1 x USB C Cable (For Charging)
Note a USB adapter does not come with the Keypad, any cell phone adapter will charge the keypad, as long as the output is 5V 2A or 5V 1A - 1x Wall Mount Bracket
- 4 x Screws & Wall Anchors
Power Indicator
Charging the Battery
STEP 1: Push the battery switch to 'On'.
STEP 2: Connect your keypad to a power outlet using the included USB C cable and your cell phone charger.
STEP 3: It will take 2 to 3 hours to fully charge the keypad battery from an empty state.
STEP 4:The power indicator will turn from a Red to a Green color (If this does not occur
How to pair the keypad with the Gen 2 Alarm System
STEP 1: Set the alarm panel into pairing mode by selecting the sensor icon on the main menu. Enter in your passcode, then select the keypad accessory icon.
STEP 2: Select the + plus sign on the top left. You will have 20 seconds to trigger the keypad.
STEP 3: Press the 'Doorbell' button to send a signal to the Gen 2 alarm panel.
STEP 4: The Keypad will sound two long beeps and the alarm panel should say 'Pair Ok'
User and Admin Passcode
The Keypad uses four, 4-digit passcodes.
1. User Passcode is used to arm, home arm and disarm the security system
2. Admin passcode is used to pair, delete RFID tags and change passcodes.
3. Default User passcode 1, is 1234, default Admin passcode is 9876
4. User passcode 2 & 3 are not enabled and can be programmed
Note: The keypad will disarm the Gen 2 alarm panel with the keypad user passcodes (max of 3 passcode) or the RFID tags (max of 10 RFID tags). The keypad will not disarm the Gen 2 alarm system using the passcodes that you have programmed into the Gen 2 alarm panel itself, however you can program the same passcodes you used for Gen 2 alarm panel so the passcodes are "synced"
Programming the admin, user and RFID tags
Pairing RFID Tag
The RFID tags supplied with this kit can be paired with the keypad. This will allow you to arm away, arm home and disarm the Gen 2 alarm panel.
STEP 1: Enter admin passcode, then press the √ check mark.
STEP 2: Press 1, then the √ check mark.
STEP 3: Touch the RFID tags to the RFID sensing area one by one
STEP 4: Then press 'X' twice to exit
Note: Up to 10 RFID tags can be added.
Deleting RFID Tags
STEP 1: Enter admin passcode, then the √ check mark.
STEP 2: Press 2, then the √ check mark.
STEP 3: All RFID tags will be cleared
Setting Admin Passcode
STEP 1: Enter admin passcode, then press the √ check mark.
STEP 2: Press 3, then press the √ check mark.
STEP 3: Enter the new 4-digit admin passcode, then press the √ check mark.
STEP 4: Re-Enter the new 4-digit admin passcode, then press the √ check mark.
Very Important: Ensure that you write down and keep the new passcode in a safe place in case you forget it.
Setting User 1 Passcode
STEP 1: Enter admin passcode, then press the √ check mark.
STEP 2: Press 4, then press the √ check mark.
STEP 3: Enter the new 4-digit user passcode, then press the √ check mark.
STEP 4: Re-Enter the new 4-digit admin passcode, then press the √ check mark.
Setting User 2 Passcode
STEP 1: Enter admin passcode, then press the √ check mark.
STEP 2: Press 5, then press the √ check mark.
STEP 3: Enter the new 4-digit user passcode, then press the √ check mark.
STEP 4: Re-Enter the new 4-digit admin passcode, then press the √ check mark.
Setting User 3 Passcode
STEP 1: Enter admin passcode, then press the √ check mark.
STEP 2: Press 6, then press the √ check mark.
STEP 3: Enter the new 4-digit user passcode, then press the √ check mark.
STEP 4: Re-Enter the new 4-digit admin passcode, then press the √ check mark.
Very Important: Ensure that you write down and keep the new passcode in a safe place in case you forget it.
Deleting User 1 Passcode
STEP 1: Enter admin passcode, then press the √ check mark.
STEP 2: To delete User 1 passcode, select number 4, then press the √ check mark twice.
Deleting User 2 Passcode
STEP 1: Enter admin passcode, then press the √ check mark.
STEP 2: To delete User 1 passcode, select number 5, then press the √ check mark twice.
Deleting User 3 Passcode
STEP 1: Enter admin passcode, then press the √ check mark.
STEP 2: To delete User 1 passcode, select number 6, then press the √ check mark twice.
How to arm 'Away', 'Home' and Disarm the Gen 2 alarm panel using the external keypad.
To 'Away Arm'
1. Press the 'Away' button
2. Enter either you Admin code, User code or touch the RFID (needs to be programmed first)
3. The alarm panel should then respond by counting down and 'Away' on the alarm panel will be highlight in orange
To 'Home Arm'
1. Press the 'Away' button
2. Enter either you Admin code, User code or touch the RFID (needs to be programmed first)
3. The alarm panel should then respond by counting down and 'Home' on the alarm panel will be highlight in Yellow
To 'Disarm'
1. Press the 'Away' button
2. Enter either you Admin code, User code or touch the RFID (needs to be programmed first)
3. The alarm panel should then respond by counting down and 'Disarm' on the alarm panel will be highlight in Green
Turn On the proximity sensor
STEP 1: Enter admin passcode, then press the √ check mark.
STEP 2: Select number 7, then press the √ check mark to turn on the proximity sensor
Turn On or Off the proximity sensor
STEP 1: Enter admin passcode, then press the √ check mark.
STEP 2: Select number 8, then press the √ check mark to turn on the proximity sensor
If you would like to reset the keypad
STEP 1: Remove the power supply, and turn off the battery switch
STEP 2: Press and hold your fingers down on the X and the √ check mark, then turn on the battery switch.
STEP 3: After holding for 10 seconds, the keypad will emit a long beep, indicating a successful reset
Installation
Doorbell